INSTALLATION

Electrical connection

Installation
EN 32
Before using the appliance for the first time check the connections
using water and washing-up liquid to ensure that there are no gas
leaks.
230–240 V~ - 50/60Hz
• Wall socket and plug must be accessible at all times.
• Make sure that the cable does not come into contact with parts of
the oven that may become hot.
• If you want to make a fixed connection, ensure that a multi-pole
switch with a distance between contacts of 3 mm is installed in the
supply cable.
• Do not use a multiple socket or an extension lead to connect the
device to the electrical mains. Safe use of the device cannot be
guaranteed with such accessories.
• When placing the cooker next to a tall cupboard or another wall
made of flammable material, keep at least 50 mm distance between
the cooker and the walls.
• Also keep a minimum distance of 650 mm between the hob and
any cooker hood placed above the cooker.
• If you place the cooker in a kitchen unit, the minimum space must
be adhered to.
• If the cooker is built in between kitchen cabinets, the lining of the
units must be able to withstand temperatures up to 90°C.
Levelling
The height of the cooker can be adjusted with the adjusting feet.
If you want to install the cooker on a platform, make sure that it is
securely fastened.
Warning!
After installation of the device, check whether the burners work
properly. The flame pattern should be regular and stable on the high
setting, and the burners must not go out on low.