3.2 Ventilation

Minimum distances required for proper ventilation:
A. Back ↔ wall
B. Right/left ↔ any piece of furniture/wall

3.3 Change of the hinge position

WARNING! Switch off and unplug the appliance before changing the
hinge position. RISK OF ELECTRIC SHOCK!
CAUTION! The change of the position must be carried out by at least
two persons; otherwise you may hurt yourself or damage the appliance.
1. Empty the appliance completely.
2. Tools required: Cross slot screwdriver, flathead screwdriver, hexagonal spanner.
3. Set the adjustable feet to their highest position.
4. You must tilt the appliance backwards to remove the door. Lean the appliance
against a solid construction and block it, so the appliance cannot slide away
while you are working.
5. The appliance must not tip over or lie on one of its sides. Otherwise you may
cause serious damage to the cooling system.
6. Keep all de-installed parts in a safe place.
1. Remove the screws and hinge bracket on the base.
2. Let the door slide down. Remove the door.
3. Remove the top hinge pin (inside the door) and refit it on the opposite side.
4. Place the door on the top hinge. Install the bottom hinge on the opposite side.
5. Check proper horizontal and vertical adjustment of the door and perfect fit of
the door seal before you tighten the bottom hinge.
6. Check again that the door is adjusted properly so you can open/close the door
smoothly.
Preparation:
Change:
26
Min. 5 cm
Min. 1 cm