5.4.2. DIP switch 2 to 6
These DIP switches can be used to set:
- Battery charge voltage and Absorption time
- Inverter frequency
- Search mode
Ds2-ds3: Setting the charge algorithm
Absorption
ds2-ds3
voltage
ds2=off
14.4
ds3=off
28.8
(default)
57.6
ds2=off
14.1
ds3=on
28.2
56.4
ds2=on
14.7
ds3=off
29.4
58.8
ds2=on
15.0
ds3=on
30.0
60.0
Ds4: Inverter frequency
Ds5: Search Mode
Store the settings by moving DIP switch 6 to 'on' and back to 'off'.
All manuals and user guides at all-guides.com
Absorption
Float
Storage
Time
voltage
Voltage
(hours)
13.8
13.2
27.6
26.4
8
55.2
52.8
13.8
13.2
27.6
26.4
8
55.2
52.8
13.8
13.2
27.6
26.4
5
55.2
52.8
13.8
13.2
27.6
26.4
6
55.2
52.8
off = 50Hz
off = off
Suitable for
Gel Victron Deep
Discharge
Gel Exide A200
AGM Victron Deep
Discharge
Gel Victron Long
Life (OPzV)
Gel Exide A600
(OPzV)
Gel MK battery
Li-ion (LiFePO4)
AGM Victron Deep
Discharge
Tubular plate or
OPzS batteries in
semi-float mode
AGM spiral cell
Tubular plate or
OPzS batteries in
cyclic mode
on = 60Hz
on = on