REPAIRS AT THE UNIT
10.2
OUTLET VALVE
1. Use a 22 mm wrench to screw the outlet valve (1) from
the paint section.
2. Carefully take out the pressure spring (2) and spring
support ring (3), ball (4) , seat (5) and seal (6).
3. Clean or replace the components.
4. Check the sealing washer (7) for damage.
5. Check the installation position when mounting the spring
support ring (3) (clipped onto spring (2)), outlet valve seat
(4) and seal (6), refer to figure.
10.3

PRESSURE CONTROL VALVE

Only have the pressure control valve (1) re-
placed by the customer service.