DISPLAYS AT THE UNIT / CLEANING THE UNIT
8

CLEANING THE UNIT

A clean state is the best method of ensuring operation with-
out problems. After you have finished spraying, clean the unit.
Under no circumstances may coating material rests dry and
harden in the unit. The cleaning agent used for cleaning (only
with a flash point above 21 °C) must be suitable for the coat-
ing material used.
Secure the spray gun, refer to the operating manual of
the spray gun.
Remove and clean the tip and tip holder.
Unit with suction system
1. Set pressure relief valve to
2. Switch the device on (Pos. I) using the ON/OFF switch.
3. Remove the suction system from the material container.
The return pipe hose remains over the material container
until barely any coating material comes out.
4. Immerse the suction system into a container filled with a
suitable cleaning agent
5. Turn the pressure control valve back in order to set a mini-
mal spraying pressure.
6. Set pressure relief valve to
7. Pull the trigger of the spray gun in order to pump the
remaining coating material from the suction hose, high-
pressure hose and the spray gun into an open container (if
appropriate, increase the pressure at the pressure control
valve slowly in order to obtain a higher material flow).
The container must be earthed in case of
coating materials which contain solvents (e.g.
by using a metal container).
See safety regulations.
8.
Set pressure relief valve to
9.
Pump suitable cleaning agent in the circuit for several
minutes.
10. Set pressure relief valve to
11. Pump the remaining cleaning agent into an open contain-
er until the pump is empty.
12. Set pressure relief valve to
13. Set ON/OFF Switch to ON/OFF .
Warm water improves the cleaning effect in
the case of water-dilutable coating materials.
(circulation).
(spray).
(circulation).
(spray).
(circulation).
8.2

SUCTION FILTER

Clean filters always ensure maximum volume,
constant spray pressure and problem-free
functioning of the unit.
1. Release screws with a screwdriver (Item 2).
2. Lift and remove filter disk (1)with a screwdriver
3. Clean or replace the filter disk.
Carry out cleaning with a hard brush and a
corresponding cleaning agent.
12