Herunterladen Inhalt Inhalt Diese Seite drucken

Repairs At The Unit - HBM Machines 10577 Bedienungsanleitung

Hochdruck airless spritzgerät farbspray wandspritzgeräte set 1400 watt
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

REPAIRS AT THE UNIT

10
REPAIRS AT THE UNIT
Switch the unit off.
Before all repair work: Unplug the power
plug from the outlet.
10.1
INLET VALVE
1. Place the enclosed 30 mm wrench on the housing (1).
2. Loosen the housing (1) with light blows of a hammer on
the end of the wrench.
3. Screw out the housing with the inlet valve (2) from the
paint section.
4. Pull of the clasp (3) using the enclosed screwdriver.
5. Place the enclosed 30 mm wrench on the inlet valve (2).
Turn out the inlet valve carefully.
6. Clean the valve seat (4) with a cleaning agent and brush
(ensure that no brush hairs are left behind).
7. Clean the seals (5, 6) and check for damage. Replace, if
necessary.
8. Check all the valve parts for damage. In case of visible
wear replace the inlet valve.
Installation
1. Insert the inlet valve (2) into the housing (1) and secure
with the clasp (3). Ensure that the (black) seal (5) is mount-
ed in the housing.
2. Screw the unit from the housing and the inlet valve into
the paint section. The same (black) seal (6) has to be
mounted in the paint section.
3. Tighten the housing with the 30 mm wrench and tight-
en with three light blows of the hammer on the end of
the wrench. (Corresponds to approx. 90 Nm tightening
torque).
14

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis