2.9 Lithium-ion (LiFePO₄) batteries
Li-ion batteries do not suffer from sulfation.
But Li-ion batteries are very sensitive to under voltage or over
voltage².
Li-ion batteries therefore often have integrated cell balancing and
under voltage protection (UVP) circuitry.
Some reverse polarity protected chargers will not recognize a
battery when the UVP has tripped.
The Blue Power Charger will however automatically reset the
UVP and start charging.
Important note:
NEVER attempt to charge a Li-ion battery when its
temperature is below 0°C.

2.10 Low current mode

Some leadead acid batteries can overheat if charged with a
current exceeding 0,3C (C is the capacity in Ah. A 12 Ah battery
for example should not be charged with a current exceeding
0,3 x 12 = 4 A). The low current mode (charge current limited to
4 A or less, see technical specifications) should therefore be used
to charge low capacity lead-acid batteries.