The hob or the cooking zone does not work:
– the hob has been poorly connected to the electrical power
supply
– the safety fuse has blown
– check the locking key has been enabled
– the touch control keys have been splashed with water or fat
– there is an object on the touch control keys
A single zone or all zones are not working:
– the safety device has been operated
– this shall engage when a cooking zone has been left on
unintentionally
– the safety shall also engage when one or more touch control
keys are covered
– a pan is empty and the base has overheated
– the hob also has an automatic power reducer and automatic
shut-down in the event of overheating
The fan continues to operate after the hob has switched
off:
– this is not a defect, the fan is protecting the electronic
equipment
– the fan will stop automatically.
The automatic cooking controller does not seem to be
working:
– the cooking zone is still warm [
– the maximum cooking level has been selected [
– the cooking level was selected using the control key [

10.2 Messages at the extraction

Code
1st LED
– Run-out function activated
flashes
– The tower was not detected at the requested
position.
– Check nothing can prevent the movement of
2 LEDs
the extraction tower
flash
– Press
– Contact Novy
– Safety switch in extraction tower constantly
activated
3 LEDs
– Press
flash
– Contact Novy
– Turn on spindle axe with a screwdriver.
– Front extraction tower glass is missing
– Front extraction tower glass has not been put
4 LEDs
in place correctly
flash
– Press
– Extraction tower detection switch faulty
H
]
]
9
].
The cooker hood does not extract well. What can be the
cause of this problem?
– Check that the top glass of the extraction tower is correctly
positioned. The suction opening must be clear.
– Check the grease filter. Follow the cleaning indication. On
average, the filter must be cleaned every two weeks to
ensure the extraction works correctly.
– Check the air supply in the house. As soon as the cooker
hood is switched on, make sure that air is supplied by
opening the grates in the windows or by opening a window.
– Check the duct for blockages or constrictions which prevent
proper extraction of the air.

10.3 Miscellaneous

Fault: In the event of a fault, please do not hesitate to contact
our Repair Service:
Belgium:
France:
Germany:
The Netherlands:
Spain:
Italy:
For all other countries, contact your local Novy installation
engineer in Belgium:
For a proper and prompt handling the Repair Service needs to
know the type of your device. This information can be found on
the type plate on the inner frame of the extraction unit.
Stick the provided sticker with the type plate and serial number
here.
– 77 –
Tel.: +32 (0)56 36 51 02
Tel.: +33 (0)3 20 94 06 62
Tel.: +49 (0)511.54.20.771
Tel.: +31088-0119110
Tel.: +34 938 700 895
Tel.: +39 039.20.57.501
Tel.: +32 (0)56/36.51.02