ble at the following internet address: www.eq-3.com
10 Technical specifications
Device short description:
Temperature measuring range:
Accuracy @ -30 to +100 °C:
Accuracy @ 0 to +80 °C:
Length of sensor cable:
Supply voltage:
Current consumption:
Standby power consumption:
Battery life:
Degree of protection:
Ambient temperature:
Radio frequency band:
Maximum radiated power:
Receiver class:
Method of operation:
Degree of pollution:
Typ. open area RF range:
Duty cycle:
Dimensions (W x H x D):
Weight:
Subject to technical changes.
Technical specifications
HM-WDS30-OT2-SM-2
-30 to +100 °C
±4 K (2x ±2.0 K)
±2 K (2x ±1.0 K)
2.8 m
2x 1.5 V LR6/mignon/AA
40 mA max.
3 µW
2 years (typ.)
IP44
-20 to +55 °C
868.0-868.6 MHz
10 dBm
SRD category 2
Type 1
2
180 m
< 1 % per h
115 x 65 x 41 mm
189 g