14. Stop

4. Turn the gas control to a"low" position and let the engine run for a while.
5. Turn off the machine on the ignition switch.
6. Turn the fuel tap to the"off" position.

15. Operation

3. When the engine has been started move the choke gradually to the right.
4. Adjust the gas to the requested speed.
a. Please draw attention to the following during operation.
b. Exhaustion must not be black. If the exhaustion is black the load is too high
or the engine has not been adjusted correctly.
c. No incorrect noises and vibrations. If these appear turn off the engine and
adjust it. Contact your Power Line dealer

16. Sparking plug

Remove the sparking plug cover.
-
-
Brush off dirt from the sparking plug.
Use a sparking-plug wrench to loosen the sparking plug.
-
-
Inspect if the isolation is intact.
Clean the sparking plug with a steel brush.
-
-
Measure the electrode distance, make sure not to damage the electrode.
The distance should be: 0,7 - 0,8 mm
-
-
If the sparking plug is okay, put it back in its place.
Put the sparking plug cover back in its place.
-