• Make a selection with the MEM button, and then confirm
the desired user memory with the START/STOP button
If you press the MEM button again, the average value of
all the stored measured values in the user memory will be
displayed. If you press the MEM button again, the aver-
age value of the last 7 days for the morning measurement
will be displayed (Morning: 5 a.m. – 9 a.m., display
you press the MEM button again, the average value of the
last 7 days for the evening measurement will be displayed
(Evening: 6 p.m. – 8 p.m., display
press the MEM button, the most recent individual meas-
ured values with date and time are displayed in turn.
• You can delete the memory by pressing and holding the
MEM button for 3 seconds. All the values in the current
user memory are deleted after three beeps are output.
• To switch off the device, press the MEM button again or
the START/STOP button
vation switch to OFF.
• If you forget to switch off the device, it will switch off
automatically after 2 minutes.

8. Transferring measurements

Connect the blood pressure monitor to your PC using the
USB cable.
No data transfer may be launched whilst performing a
measurement.
All manuals and user guides at all-guides.com
). If you continue to
or push the touch screen acti-
PC is shown on the display. Begin the data transfer
.
in the "HealthManager" PC software. During the
data transfer, an animation is shown on the
display. A successful data transfer is displayed
as in figure 1. If the data transfer is unsuccessful,
an error message appears as in figure 2. In this
). If
case, interrupt the PC connection and start the
data transfer again.
After 30 seconds of not being in use or if com-
munication with the PC is interrupted, the blood
pressure monitor switches itself off automati-
cally.

9. Error messages/trouble-shooting

In case of faults, the
Error messages may appear if:
• systolic or diastolic pressure could not be measured (
or
appears on the display)
• systolic or diastolic pressure was outside the measure-
ment range ( or Lo appears on the display)
• the cuff is fastened too tightly or loosely (
appears on the display)
• the pump pressure is higher than 300 mmHg (
appears on the display)
27
_ message appears in the display.
or
Abb. 1
Abb. 2