Problem
Bad cooling/
heating eff ects
Large noise.
The compressor
does not work.
The remote
control does not
work.
Display E1.
Display E2.
Display E4.
Full water indica-
tor illuminates
According to the European waste regulation 2002/96/EC this symbol on the product
or on its packaging indicates that this product may not be treated as household was-
te. Instead it should be taken to the appropriate collection point for the recycling of
electrical and electronic equipment. By ensuring this product is disposed of correct-
ly, you will help prevent potential negative consequences for the environment and
human health, which could otherwise be caused by inappropriate waste handling of
this product. For more detailed information about recycling of this product, please
contact your local council or your household waste disposal service.
Your product contains batteries covered by the European Directive. 2006/66/EC, which cannot be
disposed of with normal household waste. Please check local rules on separate collection of batteries.
The correct disposal of batteries helps prevent potentially negative consequences on the environ-
ment and human health.
Producer: Chal-Tec GmbH, Wallstraße 16, 10179 Berlin.
This product is conform to the following European Directives:
2014/30/EU (EMC)
2014/35/EU (LVD)
2011/65/EU (RoHS)
19
Cause
Filter mesh very dirty.
Air inlet or air outlet clogged.
Air-conditioner not put on a fl at
surface.
Initiation of overheat protection.
Too long a distance.
The remote control does not point to-
ward the receiving head of the remote
control.
The batteries have no electricity.
Pipe temperature sensor failure.
Room temperature sensor failure.
Anti-freeze protection.
The water in the baseplate of the unit
reaches the full water level.

Disposal Considerations

Declaration of Conformity

Remedy
Clean or replace the fi lter mesh.
Remove the obstruction.
Put the air-conditioner in a fl at and
fi rm place (may reduce noise).
Wait 3 minutes until the temperature
decreases and then turn on the unit.
Wait 3 minutes until the temperature
decreases and then turn on the unit.
Bring the remote control close to the
air-conditioner and ensure that the
remote control points toward the
receiving head of the remote control.
Replace the batteries.
Check the pipe temperature sensor
and related circuits.
Check the room temperature sensor
and related circuits.
Restore the functions automatically
once defrozen.
Drain the water in the baseplate.