Herunterladen Inhalt Inhalt Diese Seite drucken

Environmental Conditions; Normal Operation - Pentair Fleck 5810 XTR Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
User Guide Fleck 5810-XTR
3 .
Description
3.1.
Technical specifications
Pressure: ..........................................................Hydrostatic: 20 bar; Working: 1.4 - 8.6 bar
Maximum service flow rate (ΔP 1.72 bar): .......10.7 m
3.2.

Environmental conditions

• Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C;
• main supply voltage fluctuations up to ±10% of the nominal voltage;
• temperature from 0 °C to 52 °C;
• not directly exposed to the sun;
• installed in a dry place.
3.3.
Description and components location
3.4.
By-passing
If the system is equipped with a bypass and if a problem occurs, turn the valves to bypass the system as shown in the picture
below.

Normal operation

Softener System
In
6 / 52
3
/h
Display
Mixing device
Injector block
Out
Drain
Brine
Meter
Inlet
Outlet
In Bypass
Softener System
In
Out
Ref. MKT-UG-018 / C - 09.10.2019