5. Before starting the equipment
5.1 Electrical safety:
•
Electric supply cables and connected equip-
ment must be in perfect condition.
•
The generator is to be operated only with
•
equipment whose voltage specifications con-
form with the generator's output voltage.
•
Never connect the generator to the power
supply (socket-outlet).
•
Keep the cable length to the consumer as
short as possible.
5.2 Environmental protection
•
Dispose of soiled maintenance material and
•
operating materials at the appropriate collec-
tion point.
•
Recycle packaging material, metal and plas-
tics.
5.3 Connecting to earth
The housing is allowed to be connected to earth
in order to discharge static electricity. To do this,
connect one end of a cable to the earth connec-
tion on the generator and the other end to an ex-
ternal earth (for example an earthing rod).
6. Operation
Important! You must fi ll up with engine oil and
fuel before you can start the engine.
•
Check the fuel level and top it up if necessary
•
Make sure that the generator has sufficient
ventilation
•
Make sure that the ignition cable is secured to
the spark plug
•
Inspect the immediate vicinity of the gene-
rator
•
Disconnect any electrical equipment which
may already be connected to the generator
6.1 Starting the engine
•
Move the ventilation valve (Fig. 2a/Item A) to
the „ON" position.
•
Move the ON/OFF switch (Fig. 1/Item 10) to
position „ON" with the key.
•
Move the choke lever (11) to position IØI.
•
Start the engine with the reversing starter (12)
by pulling the handle forcefully. If the engine
does not start, pull the handle again.
•
Push the choke lever (11) back again after
the engine has started.
Anl_TC_IG_2000_SPK9.indb 19
Anl_TC_IG_2000_SPK9.indb 19
GB
Important!
When starting with the reserve starter, the motor
may recoil suddenly as it starts up, resulting in
hand injuries. Wear protective gloves when star-
ting the equipment.
6.2 Connecting consumers to the generator
•
Connect the equipment you want to use to
the 230 V~sockets (3).
•
The generator is suitable for 230 V~ AC appli-
ances only.
•
Do not connect the generator to the
household mains system as this may result
in damage to the generator itself or to other
electrical appliances in your home.
Note: Some electrical appliances (power jigsaws,
drills, etc.) may have a higher level of power con-
sumption when used in diffi cult conditions.
If in doubt, consult the manufacturer of your ap-
pliance.
6.3 Overload cut-out 2 x 230 V socket-outlets
Important! The generator is fi tted with an
overload cut-out.
This shuts down the sockets (3).
Important! If this happens, reduce the electric
power you are taking from the generator or remo-
ve any defective connected appliances.
Important! Defective overload cut-outs must be
replaced only by overload cut-outs of identical
design and with the same performance data. If
repairs are necessary, please contact your custo-
mer service center.
6.4 Switching off the engine
•
Before you switch off the generator, allow it
to run briefly with no consumers so that it can
„cool down"
•
Move the ON/OFF switch (10) to position
„OFF" with the key.
•
Close the petrol cock
- 19 -
20.08.2020 14:19:25
20.08.2020 14:19:25