Malfunction
EN
Water is
running
continuously
into the urinal
ceramic.
Flushing out of
the urinal
ceramic is
inadequate.
Water is
splashing out
from the urinal
ceramic.
Cause
Software fault
Technical fault
Flush time set incor-
rectly
Basket filter in
solenoid valve is
blocked
Throttle is not open
sufficiently
Water pressure is
too low
Flow rate is
excessive
Action
Interrupt
the power
supply for
10 se-
conds.
Contact a
skilled
person.
Contact a
skilled
person.
Set flush
time. →
See
Mainte-
nance.
Contact a
skilled
person.
Contact a
skilled
person.
Contact a
skilled
person.
Contact a
skilled
person.

Werbung