Replacing the control
Prerequisite
– The urinal ceramic has been demounted.
– By detaching the urinal ceramic, the brightness
sensor is no longer covered and the control is
deactivated.
– Current settings are saved as presettings in the
Geberit Control app (if the control is still
functional).
1
Close the flow control valve with metering
throttle and demount the control. → See
figure sequence
2
Replace the control. → See figure sequence
3
, page 545.
3
Mount the control and open the flow control
valve with metering throttle. → See figure
sequence
30
1
, page 543.
8
, page 554.
4
Open the Geberit app and establish a
connection with the device.
5
Install the urinal ceramic.
✓ The brightness sensor is covered and so
the control is activated.
6
Check the flush actuation with 0.5 l water or
with a Geberit app.
7
Use the Geberit app to make the desired
settings or apply saved presettings.