Replacing the urinal trap
Prerequisite
– The urinal ceramic has been demounted.
– By detaching the urinal ceramic, the brightness
sensor is no longer covered and the control is
deactivated.
1
Remove the control. → See figure sequence
1
, page 543.
2
Demount and dispose of the urinal trap. →
See figure sequence
3
Mount the new urinal trap.
4
Mount the control. → See figure sequence
8
, page 554.
5
Install the urinal ceramic.
✓ The brightness sensor is covered and so
the control is activated.
6
Check the flush actuation with 0.5 l water or
with a Geberit app.
36028804645336075 © 11-2022
970.152.00.0(01)
2
, page 544.
Replacing the power supply unit
Prerequisite
– The urinal ceramic has been demounted.
– By detaching the urinal ceramic, the brightness
sensor is no longer covered and the control is
deactivated.
1
Close the flow control valve with metering
throttle and demount the control. → See
figure sequence
1
2
Replace the power supply unit.
✓ The green LED lights up.
3
Mount the control and open the flow control
valve with metering throttle. → See figure
sequence
8
, page 554.
4
Install the urinal ceramic.
✓ The brightness sensor is covered and so
the control is activated.
5
Check the flush actuation with 0.5 l water or
with a Geberit app.
, page 543.