• Ensure that electrical plug connections are in flooding-safe areas; otherwise, there is a danger to life
from electric shock! If required, use suitable protective housings for the plug connections.
• Protect the mains plug from wetness! Never touch the mains plug with wet hands! There is danger to
life from electric shock!
• The mains cable or mains plug must not be cut off.
c) Operation
• The product must not be operated by children or teens. This also applies regarding persons who are not
familiar with these operating instructions. Persons with limited physical or mental capacities must only
use the product if supervised and instructed by a person responsible for them.
• Only clear, clean fresh water with a temperature of no more than 35 °C must be conveyed.
• The conveyed liquid must be clean. The build of the submersion pressure pump permits contamination
only up to a grain size of 1 mm.
• The product is not suitable for conveying potable water.
• The product is not suitable for conveying corrosive/caustic, flammable or explosive liquids (e.g. gasoline,
fuel oil, nitro diluent), grease, oils, salt water or sewage from toilets.
• The mains socket to which the submersion pressure pump is connected must be easily accessible. The
mains cable must point downwards from the mains socket so that the water running back at the cable
cannot enter the mains socket.
• If the submersion pressure pump is to be operated, e.g., in a well, it must be suitably attached, e.g. with
a rope. The rope must be able to hold at least 3 times the weight of the submersion pressure pump for
reasons of safety. Never attach the submersion pressure pump via its mains cable; also never use the
mains cable to carry, hold or submerse the submersion pressure pump!
• The product is not protected against running dry.
• The product must not be operated unsupervised.
• The product must not work in permanent operation.
• No persons must be present in the conveyed medium during operation.
• The product must not be operated in or close to explosive liquids or gases; there is a danger of explosion!
• Consequential damage caused by malfunction or interference at the submersion pressure pump must be
prevented by suitable measures (e.g. water level indicator, sensors, alarm devices, backup pump, etc.).
• The product is only suitable for use in temperate, not tropical, climates.
• Do not shut off the outlet side of the submersion pressure pump when it is in operation.
Use, e.g., a corresponding pressure switch to switch off power supply to the submersion pressure pump
in time.
The submersion pressure pump pressure must not work against the closed pressure side for more than
5 minutes to prevent damage. The water present in the submersion pressure pump will heat up even dur-
ing these 5 minutes. When the pressure side is opened, hot water will escape; danger of scalding/injury!