Herunterladen Inhalt Inhalt Diese Seite drucken

De Dietrich DPE3601X Einbau- Und Gebrauchsanleitung Seite 35

Gas-kochfeld
Inhaltsverzeichnis

Werbung

• 1
INSTALLATION
1•2 - ELECTRICAL CONNECTION:
Your hob is supplied with a H05RR-F-
T90 3-core (phase, neutral + earth)
mains cable, section 0,75 mm ²) and
must be connected to a 220-240 V~
single phase mains supply via a phase,
neutral +earth socket meeting standard
IEC 60083 or an omnipolar. The plug
must be accessible after the hob is
installed.
Cross section of the cable to be used
Cable H05RR-F - T90
Cross section of
conductors in mm²
Fuse
The protective conductor (green/
yellow) is connected to the earth
terminal
on the hob and must also
be connected to the installation's earth
terminal
(1.2.1).
If the supply cable is damaged, it must
be replaced by a cable or special set
available from the manufacturer or its
after-sales department.
So
that
references for your appliance without
difficulty in the future, we recommend
that you make a note of them on
page (6.1.1) "After-sales service and
customer relations" (that page also
tells you where to find them on your
appliance).
220-240 V˜ - 50/60
HZ gas
3 conductors, One of
which is an earth
0,75
1,5 A
you
can
find
1•3 - GAS CONNECTION:
If the hob is to be installed above
an oven or if other nearby heating
appliances could heat and damage the
gas hose, then it is essential that a rigid
pipe is installed instead.
If a flexible hose is used (as is the
case of butane gas) then it must not
be installed in a place where it may
be in contact with a moving part of
the kitchen unit or a location likely to
get cluttered.
No flexible hoses with a limited
service life may be longer than 2
metres and must be accessible for
inspection along their
They must be replaced before their
expiry date (printed on the hose).
Whatever
chosen, make sure that it is gastight
when installed, using soapy-water. In
France, you must use a hose or pipe
stamped NF Gaz .
The gas connection must comply with
the regulations in force in the country
where it is installed.
• Mains natural gas (1.3.1).
For your safety, you must choose only
the
one of the following two connections:
o Connection via a rigid
pipe with mechanical screw connectors
(½" gas standard).
• Connect directly on to the elbow on the
appliance.
8
entire length.
means
of
connection
is
copper

Werbung