Herunterladen Inhalt Inhalt Diese Seite drucken

Internal Components Map; Trouble-Shooting; Run Capacitor 50 Μf-U - IGM LAGUNA Fusion3 Gebrauchsanweisung

Tischkreissäge
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17

9.1 Internal Components Map

A. Motor
B. Dust Shroud
C. Trunnion Slides (Support)
D. Upper Trunnion
E. Lower Trunnion

10. Trouble-Shooting

Machine will not start or continues to trip the breaker.
Possible Causes
1. Start capacitor at fault.
2. Motor connection wired wrong.
3. Wiring at fault.
4. Motor Start/Stop switch at fault.
5. Motor at fault.
6. Run capacitor at fault.
7. Wall circuit breaker tripped or at fault.
8. Power supply switched OFF or at fault.
9. Plug/receptacle at fault or wired incorrectly.
Machine is excessively loud or is experiencing excessive vibration.
Possible Causes
1. Motor or component loose
2. Blade at fault
3. Motor mount loose/broken
4. Machine incorrectly mounted
5. Arbor pulley loose
6. Belts worn or loose
7. Pulley loose or at fault
8. Arbor bearings at fault
9. Motor bearings at fault
Machine trips the overload, or feels underpowered during operation.
Possible Causes
1. Feed rate/cutting speed too fast
2. Workpiece material unsuitable for machine
3. Pulley/sprocket slipping on shaft
4. Motor bearings at fault
5. Contactor at fault
6. Motor overheated
7. Workpiece crooked; fence not aligned
8. Machine undersized for task; wrong blade
9. Run capacitor at fault
10. Belt is slipping from pulley
11. Motor wired incorrectly
12. Plug/receptacle at fault
13. Motor at fault
WARNING:
1. Wiring should only be done by professional electricians. Always make sure the machine is properly earthed.
2. All wirings in the cabinets should be protected against direct contact to at least IP2X when finishing electrical installation.
3. All exposed conductive parts should be connected to the protective bonding circuit.
4. Close and lock the door of cabinets.
WARNING:
1. Enough space around the machine and the cabinets should be kept in order to maintain conveniently.
2. The machine should be installed in a workshop with good illumination and ventilation.
3. Over-voltage protection device should be provided by end user on spot.
www.igmtools.com
F. Arbor Nut
G. Arbor Washer (Flange)
H. Blade
I. Tilt Gearing
J. Height Gearing
F
C
G
H
B
N
A
E
K. Belt (behind blade)
L. Worm Screw
M. Tilt Plate
N. Start Capacitor (see spec sheet)
O. Run Capacitor (see spec sheet)
K
O
J
I
Possible Solution
1. Test/replace if faulty.
2. Correct motor wiring connections.
3. Check/fix broken, disconnected, or corroded wires.
4. Replace switch.
5. Test/repair/replace.
6. Test/replace if faulty.
7. Ensure circuit size is correct/replace weak breaker.
8. Ensure power supply is on/has correct voltage.
9. Test wires and contacts; correct the wiring.
Possible Solution
1. Inspect/replace damaged bolts/nuts, and re-tighten with thread-locking
fluid.
2. Replace warped/bent blade; re-sharpen dull blade.
3. Tighten/replace.
4. Tighten mounting bolts; relocate/shim machine.
5. Retighten/replace arbor pulley.
6. Adjust tension of/replace belt
7. Realign/replace shaft, pulley, setscrew, and key.
8. Replace arbor housing bearings; replace arbor.
9. Test by rotating shaft; grinding/loose shaft requires bearing
replacement.
Possible Solution
1. Decrease feed rate/cutting speed.
2. Only cut wood; ensure moisture is below 20%.
3. Replace loose pulley/shaft.
4. Test/repair/replace.
5. Test for good contacts/correct wiring.
6. Clean motor, let cool, and reduce workload.
7. Straighten or replace workpiece; adjust fence.
8. Use correct blade; reduce feed rate or depth of cut.
9. Test all legs for power/replace if faulty.
10. Adjust tension of/replace belt.
11. Test/repair/replace.
12. Wire motor correctly.
13. Test/repair/replace.
-16-
C
D
M

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis