Herunterladen Inhalt Inhalt Diese Seite drucken

Installing/Removing The Blade - IGM LAGUNA Fusion3 Gebrauchsanweisung

Tischkreissäge
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
Pic. 35
• Note on the Riving Knife
Limit position of the top guard
Use riving knife only with 250 mm
diameter blade
Only use this riving knife with 2 mm
and 3 mm teeth thickness
Riving knife thickness 2,3 mm
Pic. 36
Since Riving Knife, other than those offered by
Laguna, has not been tested with this product,
use of such accessories with this tool could be
hazardous. To reduce the risk of injury, only
Laguna, recommended accessories should be
used with this product.
• Note on the saw blade
No saw blade should be used where
5500 max rpm
the maximum marked speed is lower
than the selected rotational speed of
the saw spindle.
Pic. 37
www.igmtools.com
Installing/removing the riving knife
1. Unplug the tablesaw!
2. Make sure the lock is in open position
3. Insert the blade guard
4. Position the guard insert
5. Lock the blade guard
6. Reinstall throat plate
CAUTION: Make sure the blade guard is in line
with the blade. If it is not in line, please see the
Adjustment section.
3. Insert the blade guard
Pic. 38
WARNING: MAKE SURE SAW IS
UNPLUGGED.
With the throat plate removed, and the cam lock
mechanism in the open position (pulled up),
insert the blade guard insert into the slot.
4. Position to the left of the casing
Pic. 39
Make sure the guard is positioned correctly and
seated in the bottom of the casing. Grasp the
pawls with one hand, leaving the other hand
free to activate the cam action lock.
5. Lock the blade guard
Pic. 40
Keep firm hold of the blade guard with left hand
and engage the cam lock with the thumb of
your right hand.
6. Reinstall the throat plate
Pic. 41
-10-
Grasp the pawls up and out of the way to re-
insert the throat plate. Lock the throat plate.
Pic. 42
CAUTION: Make sure the riving knife is in-line
with the blade. If it is not in line, please see the
Adjustments Section.

6.7 Installing/removing the Blade

1. Unplug the table saw!
2. Remove any blade guards, riving knifes, and
the throat plate to access the blade.
3. Set the arbor tilt to 0 degrees and lock.
4. Raise saw to highest position.
5. Engage blade lock (red component).
6. Remove the arbor nut and flange with arbor
wrench.
7. Remove or install blade.
CAUTION: Make sure the teeth of the blade are
facing the front of the saw as shown.
2. Remove all accessories
Pic. 43
WARNING: MAKE SURE SAW IS
UNPLUGGED. To access the blade remove all
accessories around the blade, including riving
knifes, throat plates, ect.
3. Set arbor tilt to 0 and lock.
Pic. 44
Set the arbor tilt to 0 degrees and lock the arbor
to prevent it from moving when installing or
removing blades.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis