14. Cleaning and maintaining the device

The device should be cleaned from time to time.
This should be done using a damp cloth and, if necessary, a small amount of detergent.
IMPORTANT
– Never use harsh solvents or cleaning products!
– Never submerge the device in water!
– Do not clean the device in the dishwasher.

15. Disposal

Empty, completely flat batteries must be disposed of through specially designated collection boxes, recycling
points or electronics retailers. You are legally required to dispose of the batteries.
The codes below are printed on batteries containing harmful substances:
Pb = Battery contains lead, Cd = Battery contains cadmium, Hg = Battery contains mercury.
For environmental reasons, do not dispose of the device in the household waste at the end of its service life.
Dispose of the device at a suitable local collection or recycling point in your country.
Dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment).
If you have any questions, please contact the local authorities responsible for waste disposal.
Dispose of packaging in an environmentally friendly manner

16. What if there are problems?

If the scale encounters an error during measurement, the following is displayed:
Display
Cause
Maximum weight capacity of 200 kg
ERROR:_OVERLOAD
exceeded.
Batteries are nearly flat.
LOW_BATTERY
30 measurements have been stored.
MEMORY_FULL
ERROR:_CONTACT
The electrical resistance between the
electrodes and the soles of the feet is too
ERROR
high (e.g. with very hard skin).
ERROR:_DATA
The BIA measurement was successful, but
the fat percentage is outside the measur-
able range (less than 3% or greater than
65%).
Empty display
Batteries are completely flat.
The batteries are not inserted properly.
Unknown measurement as it is outside the
Only weight is dis-
played, no diag-
user assignment limit or a unique assign-
nosis
ment is not possible.
Incorrect weight measurement
Possible faults
Incorrect zero point of scale.
Scale is on a carpet.
Solution
Switch the scale on, wait approx. 5 seconds and repeat the measurement.
Place the scale on a flat, solid surface.
Stand on the outside of the scale as far as possible without it tipping.
When using on carpeted floors, please attach the supplied feet for the carpet.
31
20
PAP
Solution
Loads must be limited to 200 kg.
Replace the batteries (see section on chang-
ing the batteries).
Transfer the measured values.
Repeat the measurement barefoot. Dampen
the soles of your feet slightly. If necessary,
remove hard skin on the soles.
Hold the hand electrodes with the fingers
behind and the balls of the thumb in front.
Please repeat the measurement barefoot, or
with the soles of the feet lightly dampened
if necessary. If necessary, change your set
activity level.
Replace the batteries (see section on chang-
ing the batteries).
Check for correct polarity, (see "Initial use" ->
"Changing the batteries").
Select user on the scale using the [
ton or repeat user assignment in the app.
Hold the electrodes of the handheld unit and
stand barefoot on the scales.
] but-