Herunterladen Inhalt Inhalt Diese Seite drucken

Dräger X-am 2800 Gebrauchsanweisung Seite 70

Vorschau ausblenden Andere Handbücher für X-am 2800:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
en
|
Technical data
during operation and storage
Degree of protection
Alarm volume
Orientation
Storage time of gas detector
Storage time of sensors
Power packs for temperature class T4
(-40 to +50 °C, use in explosion-hazard areas):
NiMH power packs type: HBT 0010
Electrical parameters for the
2)
charging pins
:
Dimensions
Weight
Update interval for the display
and signals
Range of Bluetooth
1)
Tested with power pack HBT 0010 (order no. 3703880)
2)
The parameters are complied with when using the battery charger specified by Dräger.
Operating time for X-am 2800 under normal conditions (diffusion mode)
with CatEx and 3 EC sensors
with 3 EC sensors
70
-20 to +50 °C (measuring function and stor-
age)
-40 to +50 °C (use in areas subject to explo-
sion hazards)
700 to 1300 hPa (measuring function)
800 to 1100 hPa (use in areas subject to
explosion hazards)
10 to 90 % (briefly up to 95 %) rel. hum.
IP 68
>90 dB (A) at a distance of 30 cm
Any
1 year
The ambient conditions and storage time for
sensors in original packaging correspond to
that of the gas detector
U
I
m
approx. 130 x 48 x 44 mm (H x W x D)
Typically 220 to 250 g, depending on the
sensor configuration
1 s
®
approx. 95 m (line of sight)
1)
= 4.6 V
m
= 1.36 A
Typically 12 h
Typically 100 h
X-am
®
®
2800 / X-am
5800
1)
:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

X-am 5800

Inhaltsverzeichnis