Herunterladen Diese Seite drucken

Kärcher HWE 4000 Gas Originalbetriebsanleitung Seite 37

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
List of nozzles
Spray jet
Order No.
Description (spray angle 25°)
Minimum water quantity
Pressure
Equivalent diameter
Recoil force
Kärcher internal cleaner
Water flow-rate
l/h
Pressure
MPa
Number of nozzles
--
Nozzle size
--
Order No.
--
Attachment sets
Pump module HDI 38/12 or HDI 30/10
HWE 4000 can be operated with each pump module that has the
corresponding technical data.
This is 100% guaranteed with the Kärcher pump module HDI 38/
12 or HDI 30/10.
It can be equipped with the following attachments:
– Pressure release for star/ delta startup
– Automatic mechanism for quantity regulation for spray jet op-
erations
– Swimmer tank for mains separation
– Pressure switch for hydraulic switching
– Detergent dosing for suction-side addition
Steam stage attachment set
Order No.
2.638-006.0
Set of components for safely operating the HWE 4000 as steam
generator (below 140 °C).
Half-load attachment set for steam stage
Order No.
HDI 38/12
2.642-248.0
Order No.
HDI 30/10
2.642-896.0
Special components set for the pump module HDI 38/12 or HDI
30/10 in connection with the attachment kit steam stage for the
HWE 4000.
Attachment set for spray jet operations
Order No.
2.638-341.0
Attachment set for safe operation of the HWE 4000 in spray lance
operation (reduced flow rate below 1,800 l/h with smallest burner
capacity).
6.415-681.0
2512 EG
l/h
1450
MPa
10
mm
2,16
N
60
3000
3900
3900
6000
80
50
80
50
2
2
2
2
2,5
3,1
2,9
3,8
5.765-
4.765-
5.765-
4.765-
018.0
030.0
025.0
008.0
15
-
EN
37

Werbung