Control elements
A
A Control panel gas burner
B Control panel temperature controller
Control panel gas burner
Unlocking burner faults
 Press the key for releasing the burner fault.
Info mode
Note: The info mode can be called up only during the operating
mode in each state of the burner.
 Press the key for approx. 0.5 seconds.
You will see a display with an info number and a value dis-
played after it.
Example: Consumed fuel = 1772 l/m
–weishaupt–
Info No.
Displayed value
0
Consumed fuel (captured via the input of the im-
pulse counter)
1
Operating hours Stage 1
2
Operating hours Stage 2
3
Number of burner starts that have been carried
out
4
Software no. of the firing manager
5
Creation date of the software
6
Appliance no.:
7
Appliance testing date
8
Current eBUS address
9
Oil monitoring function
10
Current eBUS address of regulator
28
B
3
3
l/m
The system goes back to displaying the operating status after info
number 10 or if there is a waiting period of 20 seconds.
To go to the next information:
 Press the key for approx. 0.2 seconds.
Service mode
Note: The service mode may only be accessed by Customer Ser-
vice.
Control panel temperature controller
9
8
1 Conditions of the switching outputs Out 1-3
LED 1: Burner capacity is increased
LED 2: Burner capacity is decreased
LED 3: Limit value exceeded
2 LED OK: Is on when the limit value is not exceeded
3 Actual value reading
4 Entry in error list present
5 Set nominal value
6 Call error list (if entry present)
7 Up/Down keys for changing the nominal value
8 PC connection (only for customer service)
9 Steam operation set, changing the nominal value not possible
Colours of the LEDs:
– LEDs 1, 2, 3: yellow
– LED OK: green
– Other LEDs: red
6
-
EN
1
2
3
OK
SG
SP.x
Ada
Err
F
KS 40-1
burner
1
2
3
4
5
6
7