Herunterladen Inhalt Inhalt Diese Seite drucken

Panasonic CS-XZ20XKEW-H Bedienungsanleitung Seite 24

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Troubleshooting
How to retrieve error codes
If the unit stops and the TIMER indicator blinks, use the remote control to retrieve the error code.
Press for
1
5 seconds
Press for 5
3
seconds to quit
checking
• For certain errors, you may restart the unit for limited operation if there are 4 beeps when operation starts.
Diagnostic
Abnormality/Protection control
display
H 00
No memory of failure
Indoor/outdoor abnormal
H 11
communication
H 12
Indoor unit capacity unmatched
Indoor intake air temperature sensor
H 14
abnormality
Outdoor compressor temperature
H 15
sensor abnormality
Outdoor current transformer (CT)
H 16
abnormality
Outdoor suction temperature sensor
H 17
abnormality
H 19
Indoor fan motor mechanism lock
Indoor fl oat switch operation
H 21
abnormality
Indoor heat exchanger temperature
H 23
sensor 1 abnormality
Indoor heat exchanger temperature
H 24
sensor 2 abnormality
H 25
Indoor ion device abnormality
H 26
Minus ION abnormality
Outdoor air temperature sensor
H 27
abnormality
Outdoor heat exchanger temperature
H 28
sensor 1 abnormality
Outdoor discharge pipe temperature
H 30
sensor abnormality
H 31
Abnormal swimming pool sensor
Outdoor heat exchanger temperature
H 32
sensor 2 abnormality
Indoor/outdoor misconnection
H 33
abnormality
Outdoor heat sink temperature sensor
H 34
abnormality
Indoor/outdoor water adverse current
H 35
abnormality
Outdoor gas pipe temperature
H 36
sensor abnormality
Outdoor liquid pipe temperature
H 37
sensor abnormality
H 38
Indoor/outdoor mismatch (brand code)
Abnormal indoor operating unit or
H 39
standby units
* Some error code may not be applicable to your model. Consult an authorised dealer for clarifi cation.
24
Press until you hear beep
2
sound, then write down the
error code
Turn the unit off and
4
inform the error code to an
authorised dealer.
Diagnostic
Abnormality/Protection control
display
Abnormal wiring or piping
H 41
connection
H 50
Ventilation fan motor locked
H 51
Ventilation fan motor locked
Left-right limit switch fi xing
H 52
abnormality
H 58
Indoor gas sensor abnormality
H 59
Eco sensor abnormality
Outdoor high pressure sensor
H 64
abnormality
H 67
nanoe abnormality
H 70
Light sensor abnormality
DC cooling fan inside control board
H 71
abnormality
H 72
Abnormality tank temperature sensor
Abnormal communication between
H 85
indoor & wireless LAN module
H 97
Outdoor fan motor mechanism lock
H 98
Indoor high pressure protection
H 99
Indoor operating unit freeze protection
F 11
4-way valve switching abnormality
F 16
Total running current protection
Indoor standby units freezing
F 17
abnormality
F 18
Dry circuit blocked abnormality
F 87
Control box overheat protection
Power factor correction (PFC) circuit
F 90
protection
F 91
Refrigeration cycle abnormality
Outdoor compressor abnormal
F 93
revolution
Compressor discharge pressure
F 94
overshoot protection
Outdoor cooling high pressure
F 95
protection
Power transistor module overheating
F 96
protection
F 97
Compressor overheating protection
F 98
Total running current protection
Outdoor direct current (DC) peak
F 99
detection

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis