Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Hama Mini Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Mini:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
4.4 Random mode
When random mode is activated, the connected device
is switched on or off at irregular intervals (see table).
Switched on
at least
10 minutes
Maximum
26 minutes
Activation
• First proceed as described in 5. Operation and
activate the AUTO operating mode.
• Press the RND button (4) to start random mode. R is
shown in the upper right corner of the display.
• The connected device is now switched on or off at
irregular intervals, but within the intervals indicated
in the table.
• Press the RND button (4) again to end random
mode. The R indicator goes out.
5. Operation
• Make all settings according to your wishes - as
described in 4. Commissioning.
• Switch off the device that is to be plugged into
the timer.
• Plug the device into the socket of the timer using
a mains plug.
• Connect the timer to an approved and easily
accessible wall socket.
• Switch the connected device on. This is then
switched on and off according to your settings
via the timer.
• Press the ON/OFF button (5) repeatedly to switch
between the operating modes (ON/AUTO/OFF). The
current mode is shown on the display
Operating
mode
ON
AUTO
OFF
Switched off
26 minutes
42 minutes
Function
The connected device remains
permanently switched on. Set
programs are not executed.
The connected device is
switched on and off at the
set times.
The connected device remains
permanently switched off. Set
programs are not executed.
Note
• Note that the programmed on and off times,
the countdown and random mode can only be
activated when the timer is in AUTO operating
mode.
• Also note that when the countdown or random
mode is activated, the programmed switch-on
and switch-off times are not executed.
Reset
Press the RESET button (9) to reset the timer to the
factory setting. All settings that have already been
made will be lost.
6. Care and maintenance
Note
Disconnect the device from the mains before
cleaning and during prolonged periods of non-use.
• Only clean this product using a lint-free, slightly
damp cloth and do not use any harsh cleaners.
7. Warranty disclaimer
Hama GmbH & Co KG assumes no liability and provides
no warranty for damage resulting from improper
installation/mounting, improper use of the product or
from failure to observe the operating instructions and/
or safety notes.

8. Technical data

Electrical voltage
Max. connected load
(resistive load)
Protection class
Protection
Operating temperature
Standby power
Time setting interval
Storage buffering
(when not in use)
Battery type
Timer switch
230 V ~ / 50 Hz
1800 W
1
IP20
0°C – +55°C
approx. 0.6 W
1 minute
max. 180 days
Ni-MH 1.2 V
40 mAh
5