Herunterladen Inhalt Inhalt Diese Seite drucken

Other Precautions - Cristec YPOWER 12V/25A Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für YPOWER 12V/25A:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 44
Precautions regarding inflammable materials
The charger should not be used near inflammable
materials, liquids or gases.
The batteries can emit explosive gases : please follow
the manufacturer's instructions carefully
installing them.
Nearby the batteries : ventilate the area, do not
smoke, do not use any open flame.
Use fuses as defined in this manual.
Ignition protection (Protection against ignition of
surrounding flammable gases)
YPOWER 12V/40A without option is protected against
ignition of flammable gases following the ISO 8846
standard.
The DC output fuses F500 and F501 should only be
replaced by the following blade fuse :
Label : F500, F501,
Manufacturer : BUSSMAN
Reference : BK-ATC-25M Rating : 32V-25A

Other precautions

Never attempt to drill or to machine the charger's case
: this may damage components or cause metal chips
or filings to fall on the charger's board.
Do not do anything that is not explicitly stated in this manual.
Quantity : 2
when
27

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis