Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BAE PD-ML-010-04 Bedienungsanleitung Seite 73

Vorschau ausblenden Andere Handbücher für BAE PD-ML-010-04:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BAE PD-ML-010-04
Configuration Tool + USB-Adapter
8
Specific functions of BML BM1/BM2 (continued)
8.2.3
Real time errors
The real time errors are displayed with the help of LEDs:
Real time errors
Possible cause
Nonius signal overdriven
Air gap between sensor module and magnetic disc/
magnetic tape is too great.
Nonius signal too low
The working range of the sensor module has been
exceeded or the magnetic disc/magnetic tape is
defective.
Master signal overdriven
Air gap between sensor module and magnetic disc/
magnetic tape is too great.
Master signal too low
The working range of the sensor module has been
exceeded or the magnetic disc/magnetic tape is
defective.
Plausibility error in period
Plausibility check of the absolute signal fails or no
counter
calibration performed.
ABZ frequency error
Calibration failed, sensor module defective.
Frequency counter of the
Calibration failed, sensor module defective.
internal converter
Tab. 8-5:
Real-time errors of BML BM1/BM2
www.balluff.com
Troubleshooting
► Check orientation of the sensor
module to the magnetic disk or
magnetic tape and/or repeat
calibration.
► Check supply voltage and/or
repeat calibration.
► Replace sensor module.
english
35

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis