Specific functions BML-S1G (continued)
Calibration Wizard
1. Open the calibration window (see
chapter 6.1.5 on page 17), define the number of
poles on the ring and press <Enter> to start the
configuration process. Do not interrupt this process to
avoid malfunctions.
Fig. 6-3:
Enter/change number of poles
2. After the parameter calculation is done, you can start
the calibration process with the Start
button.
3. After the calibration is started, rotate the ring in the
forward direction at a constant and slow speed until
the S
message is displayed. During the
tOp rOtatiOn
forward movement, follow the instructions displayed in
the window (e.g. wrong direction).
4. If the forward direction was successfully measured,
move backward with constant and slow speed until the
S
message is displayed. During the
tOp rOtatiOn
backward movement, follow the instructions displayed
in the window.
5. If the backward direction was also successfully
measured, the parameters will be updated in the BML.
Do not interrupt this process to avoid malfunctions.
6. If the update succeeded, the following message
appears on the screen:
Fig. 6-4:
Enter/change number of poles
18
english
Possible errors, troubleshooting
Parameters (e.g. number of poles) are not correctly
defined or the mechanical settings (e.g. air gap, side
offset and tangential offset) are critical.
Fig. 6-5:
► Check the parameters, adjust the mechanical
!
At the end of the calibration procedure the message
CaLiBratiOn
ERROR. Calibration failed. may appear and means that
the mechanical settings need to be corrected (e.g. air
gap, lateral and tangential offset).
► Adjust the mechanical settings (e.g. set a smaller
Communication related and other errors
► Check connections and refer to chapter 6.1.5 on
Deleting calibration
The current calibration can be deleted by clicking on
DeLete
will be set back to linear operation.
Another option to clear the rotative calibration is to use the
built-in factory defaults function (see chapter 5.3.3 on
page 14).
Aborting calibration
The calibration can be aborted by clicking on a
calibration window. The calibration will be aborted and the
BML parameters will be set back to linear operation.
Parameters not defined correctly or mechanical
settings not ideal
settings and repeat the calibration.
air gap, side offset and tangential offset).
page 17.
! With this function the BML parameters
CaLiBratiOn
in the
BOrt