Specific functions of BML BM1/BM2 (continued)
Calibration
The calibration differs depending on the set application
type.
Rotative mode (axial)
Calibration is automatically performed in this mode. To do
this, start the application (e.g. the motor).
Fig. 8-5:
Start rotation
As soon as the speed is constant, click on n
then carries out the calibration. After calibration is
complete, the result is displayed.
30
english
Rotative mode (radial) / linear
In this mode or for segment calibration, you must move
multiple times from the start position to the end position. In
a linear 3-track system, both sensor chips are calibrated
one after the other. At the end, a synchronization of the
two chips is performed. To do this, follow the instructions
of the Calibration Wizard.
Fig. 8-6:
. The Tool
eXt
Move to start position
With segment or linear calibration, proper
system operation can only be guaranteed within
the calibrated range.