The compressor is working,
but no ice cubes are produced.
Ice cubes stick together
Warning indicator for too little
water lights up
The compressor works, but no
ice cubes are produced
Visual error messages:
1 x flashing: Water temperature sensor (325-5157) is defective.
2 x flashing: Ambient temperature sensor is defective (325-5125).
3 x flashing: Reservoir temperature sensor (325-5009) for reservoir jam is defective.

CIRCUIT DIAGRAM

EB 26
Stand 05/23 SvN
Leak in the cooling system? Notify a technician.
Condenser dusty?
Too little water? Check water supply.
Leak in the cooling system? Notify a technician.
Do not leave the ice cubes in the storage container for a long time. It is not used to store
the ice cubes.
Water supply disturbed, check the supply.
Valve damaged. Check the valve and replace it if necessary.
Water pressure too low. The water pressure must be at least 1 kg/cm2.
Leak in the cooling system. Have the cooling system checked by a specialist.
Condenser is dusty. Remove the dust, clean the ventilation slots.
(all variants must be replaced by a specialist)