Limitations on use

WARNING
Beards and sideburns in the sealing area of the full face mask will cause
leakages. Therefore, the full face mask should not be used by anyone with
facial hair of this sort. Earpieces in the sealing area also cause leakages.
► Use special mask spectacles.
3.5

Approvals

The full face masks are approved according to:
EN 136:1998 Cl. 3 or Cl. 2
TP TC 019/2011
(EU) 2016/425
(EU) 2016/425 as brought into UK law and amended
Declarations of conformity: see www.draeger.com/product-certificates
The full face masks comply with the U.S. NIOSH regulations.
They are approved according to AS/NZS 1716:2012 in Australia and New
Zealand.
The full face masks may only be used with approved powered air-purifying
respirators, normal-pressure airline equipment or respiratory filters with round-
thread connectors according to EN 148-1 (RA).
The full face masks are tested in accordance with 2014/34/EU for use in
explosion-hazard areas and can be used in the following zones:
12
Zone 0, 1, 2 for gases
in explosion group IIA, IIB, IIC
Zone 0, 1, 2 for gases
in explosion group IIA, IIB
Zone 1, 2 for gases
in explosion group IIA, IIB, IIC
Zone 1, 2 for gases
in explosion group IIA, IIB
Dust explosion-hazard
areas of zone 21, 22
3.6

Type-identical marking

The facepieces are marked differently:
Connector
RA
Mask body
EPDM or Si
X-plore 6300 EN 136:1998 CL. 2 or
X-plore 6500 EN 136:1998 CL. 3
CExxxx (notified body in Europe)
Visor
L, PC or PMMA
Instructions for use