Description
2.2

Theory of Operations

The Benchtop Peristaltic Dispenser transfers low viscosity liquids by pressure
displacement applied by a turning rotor against a tube carrying the material. Usually
these pumps are chosen because the liquids are hazardous or difficult to work with
and it is advisable to limit operator contact. Another reason is that peristaltic pumps
are air free.
Dispense outputs can be timed from 0.01 - 99.99 seconds with flow speeds from
0.01-6 ml/min using PTFE tubing. The pump is bi-directional allowing suck-back after
dispense to prevent dripping of the fluid.
When dispensing UV adhesives use only black tubing. This avoids curing of the
adhesive in the tube.
The amount of product dispensed is controlled by:
– The dispensing time.
– The size of the used feedline.
– The speed of the drive.
– The size of the dispensing needle.
Various sizes of PTFE tubes, the corresponding applicator nozzles and dispensing
needles are available, see section 7.1.
3

Technical Data

Power supply
Power Consumption
Fuse
Dispensing time range
Rotor speed
Flow rate
Direction of rotation of the drive
Operating Temperature
Relative Humidity
Weight
WARNING:
Unplug power cord
prior to removing cover.
98548
110/220 V AC ± 10%, 50/60 Hz
~0.3 A
T1A fast-acting (Glass type, 5 x 20 mm)
0.01 - 99.99 sec
Up to max. 120 rpm (CW/CCW)
0.01 - 6 ml/minute with PTFE feedline
Clockwise (CW)
Counterclockwise (CCW)
+5°C - +50°C (+41°F -122°F)
Max. 80%
3 kg
TIME DISPLAY
POWER
4
6
2
8
0
10
SPEED
0
10
0
VACUUM
V.INT
190 mm
7.46"
R.C
MODE
TIMER
CONT.
CW
DRIV
CCW
10
OUT
IN
7