4
Setup and Operation
• Wait 2 minutes (1.) to let the tube
regain its shape.
• Cut the PTFE tube as shown is the
right graphic (2.).
• Install the required dispensing needle.
4.3.3
Mounting the Feedline to the Product Bottle
Dispensing Cyanoacrylate:
• Cut the nozzle of the bottle only as
much as it is necessary to insert the
tube.
☞
It is necessary to minimize moisture
access to the bottle that causes curing of
the CA.
Dispensing Anaerobic:
• Unscrew the dispensing cap.
• Cut the tube in the way described in
the right graphic.
• Insert the tube into the bottle.
4.3.4
Setup of the Dispensing Quantity
TIMER MODE:
• Switch button MODE 2 to TIMER.
• With the button
• With the buttons
After a few seconds the adjusted time is set.
• Switch button DRIVE 9 to the direction of rotation, which the manual applicator is
connected to the tube.
Direction of rotation:
CW - clockwise
• With the Speed Adjustment Knob 3 choose a speed.
• Initiate a start to check the dispensed quantity.
If the dispensed quantity is too small:
• Increase the dispensing time and/or the speed of the drive. Check the dispensed
quantity again. Repeat this sequence until the desired dispensed quantity is
achieved.
If the dispensed quantity is too high:
• Decrease the dispensing time and/or the speed of the drive. Check the dispensed
quantity again. Repeat this sequence until the desired dispensed quantity is
achieved.
If the desired dispensed quantity is not within reach:
• Change the feedline to a smaller/bigger size and repeat the above steps.
10
the digits of the display can be chosen separately.
and
the required dispensing time can be chosen.
CCW - counter clockwise
1.
2.
CA