5. Commissioning, operation
5.2 Mounting the radio unit
For example with WIKA measuring instrument model PGU23.100
®
NETRIS
3 and WIKA measuring instrument are not connected
EN
®
NETRIS
3 and WIKA measuring instrument are connected through direct mounting
To mount the WIKA radio unit on the rear of the model PGU2x.100 case, only use the short
screws from the scope of delivery. Tighten with a torque of 1.5 Nm. The WIKA radio unit
may only be installed on the WIKA measuring instrument up to the maximum allowable
temperature at the measuring instrument of 60 °C [140 °F]. If the maximum allowable
temperature is exceeded, the possibility of mounting away from the measuring location
®
must be used, see „NETRIS
3 and WIKA measuring instrument are connected at a
distance (wall mounting)".
®