BIR 01-_ _ _ _-K1_ _ L_... / BIR 02-_ _ _ _-P1 _ _ L _...
Inductive Rapid Positioning System
5
Secondary Device Functions (continued)
State
The current status can be read under State.
Bit
Name
Description
0
Vibration
The vibrations are above the
threshold value.
1
Upper
The temperature is above the
Temperature
threshold value.
2
Lower
The temperature is below the
Temperature
threshold value.
3
Internal
The humidity is too high.
Humidity
Tab. 5-32: Extreme environment status – State
Time
Under Time, the summed time in seconds in which the
device was exposed to an extreme condition can be read
out.
5.7.5
System Commands
Command Value Device Action
0x81 (129)
Application Reset – Resets writable
parameters to the default value.
0x82 (130)
Reset Factory Settings – Resets
writable parameters to the default
value.
0xA5 (165)
Maintenance Reset – Resets the
value for Time and Flags.
Tab. 5-33: Extreme environment status – System Commands
For an overview of all System Commands, see chapter 3.5
on page 18.
5.7.6
Events
Event
Event
Event –
Code
Type
Description –
Remedy
0x8D13
Warning
One or more
(36115)
extreme conditions
present.
Tab. 5-34: Extreme environment status – Events
5.7.7
Variant Dependence
The functionality is available in all variants.
www.balluff.com
Device
Status
0 – Device
is operating
properly.
english
47