2. Ensure the frame is square within the recess by using a measuring device.
Measure the outside corner of the frame to the opposite outside corner and
repeat for the other two corners. These measurement should be within
3 mm of each other (fig. 9, page 7).
3. Fix the frame with the screws to the ceiling (fig. 0, page 7).
If packing of tracks is required do not fully tighten the screws before packers
are in place as this can cause damage to the tracks.
It might be easier to loosely fit the four corner screws (1.) first to position and
hold the blind while the main fixings (2.) are fitted.
7.3
Fitting the moving rails and fabric cassette panels
Before fitting the fabric panel observe the following:
• Check whether the moving rail is square and moves freely before fitting any
of the other panels. If the moving rail is not square it can be adjusted as shown
(fig. 8, page 6).
• Ensure that the gliders are inserted into moving rail correctly and are free to
move (fig. a, page 8).
For fitting the blind panels proceed as follows:
1. Fit the moving rail (fig. a, page 8, 1 and 2). Dependent on the version the
blind is equipped with one or two moving rails.
• Connect the power (see chapter "Electrical installation" on page 17) and
drive the moving rail away from the head rail before fitting the panels. There
is not enough space to fit the panels with the shoes in the shipped position.
2. Clip the fabric cassette panel to the shoes (fig. a, page 8, 3 and 4).
7.4
Fitting the cover (optional)
➤ Proceed as shown (fig. b, page 9).
7.5
Electrical installation
The electrical power supply must be connected by a qualified electrician who
has demonstrated skill and knowledge related to the construction and opera-
tion of electrical equipment and installations and has received safety training to
identify and avoid the hazards involved.
The powered blinds are available for a connection to a 12/24 Vg power supply.
The data plate on the head rail provides important information on the specifica-
tions of the motor.