Herunterladen Inhalt Inhalt Diese Seite drucken

Eaton Xenon beacon XB11 Bedienungsanleitung Seite 6

Inhaltsverzeichnis

Werbung

Xenon beacon XB11
English
3.0 Operation
The operating voltage of the unit is stated on the unit label. The unit can be powered directly or initiated via a telephone
ringing signal if requested when ordered.
General arrangement
2 M5 X 10 ±1
DIRECT
MOUNTING
HOLES
4.0 Maintenance
During the working life of the unit, it should require little
or no maintenance. GRP will resist attack by most acids,
alkalis and chemicals and is as resistant to concentrated
acids and alkalis as most metal products.
However, if abnormal or unusual environmental conditions
occur due to plant damage or accident etc., then visual
inspection is recommended.
If the unit requires cleaning, then only clean exterior with
a damp cloth to avoid electro-static charge build up.
Replacement of the xenon tube (see below) can be
carried out by competent site personnel. Other repairs
should be undertaken by returning the unit to MEDC or by
an authorised repairer of Ex equipment.
If a unit fault should occur, then the unit can be repaired
by MEDC. All parts of the unit are replaceable.
If you acquired a significant quantity of units, then it
is recommended that spares are also made available.
Please discuss your requirements with the Technical Sales
Engineers at MEDC.
Removing/replacing xenon tube
CAUTION: Before removing the cover assembly,
ensure that the power to the unit is isolated.
Unscrew and remove the 6 off M5 (4.0mm A/F hexagon
key). Keep in a safe, accessible location as they are
noncaptive.
Twist the cover assembly gently clockwise and
anti-clockwise, whilst pulling it away from the base.
Remove to gain access to the interior.
Unscrew and remove the two M3 nuts and washers
holding the circuit board to the cover pillars. Keep in a
safe accessible location.
2
Xenon beacon Xb11 TM135 February 2023 www.eaton.com
2 FIXING HOLES
ø8.5 ± 1
OPTIONAL GUARD
ENTRY
« L »
Lift the electronics assembly away from the support
pillars, thus exposing the xenon tube. Remove the old tube
by unscrewing the terminal block fixings. The replacement
tube can now be fitted (see xenon tube installation sheet,
which is supplied with the replacement tubes).
Replace the electronics assembly onto the support
pillars and secure using the two off M3 nuts and
washers. Ensure the retaining strap is fitted to one of the
electronics assembly mounting pillars during re-assembly.
Carefully replace the cover assembly back onto the base,
avoiding damage to the mating surfaces. Replace the 6 off
M5 screws (4.0mm A/F hexagon key) into the holes in the
cover assembly and tighten evenly. Ensure the O-ring is
seated correctly on the cover during re-assembly. Ensure
the required maximum gap of 0.2mm is maintained
between the cover and the base once assembled.
5.0 Certification/approvals
IECEx units
Certified to: IEC60079-0, IEC60079-1 and IEC60079-31
Ex d unit (IEC certification No. IECEx BAS 10.0101)
Ex d IIB Tx (Tamb.) Gb
Ex tb IIIC Tx (Tamb.) Db IP66/IP67
Gas T-rating (Tx)
T4
T5
T6
ENTRY
'R'
ambient temp
Dust T-rating (Tx)
range (Tamb.)
T105°C
(-55°C to +70°C)
T90°C
(-55°C to +55°C)
T75°C
(-55°C to +40°C)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis