Herunterladen Inhalt Inhalt Diese Seite drucken

Gas Connection; Water Connection - TTulpe Indoor B-6 P37 Eco Installations-, Gebrauchs- Und Wartungsanleitung

Vorschau ausblenden Andere Handbücher für Indoor B-6 P37 Eco:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

- The adjacent area is not lower than the area to ventilate as this might
lead to an opposing draught (this can be caused by other devices that
operate on the basis of combustion, a fireplace or any suction device
that have not been given an adequate air supply)
- The air flow from the adjacent area occurs freely through permanent
openings.
Electrical connection to battery (fig. 2)
The device is powered by a 1.5 V battery, alkaline long lasting model LR20,
thus it is not necessary to connect the device to a power socket.

Gas connection

Determine the pipe diameter according to current regulations. Before
installing the device blow in the gas pipe to eliminate any residue from
its manufacturing. Connect the water heater to the internal system's gas
pipes and place a tap above the device for the halting and release of gas.
The main gas supply pipe must be connected by a flat seat fittings that
allows the insertion of a gasket specifically provided for gas connections.
Do not use a conical seat fittings or union conical with threading sealed
with hydraulic hackled hemp or teflon.
The water heaters that are powered by tanks of L.P.G. gas with regulation
and interception devices, must be connected correctly so to guarantee
the safety of persons and the surrounding area.
Follow all related regulations.
When initially installing the device qualified persons must perform the
following tests:
- Check that the internal and external parts of the gas supplying device
are sealed;
- check that the gas quantity supplied is equal to that required by the
device;
- check that the device receives the type of gas it is manufactured to
process;
- check that the gas supply pressure does not go beyond the maximum
pressure values displayed on the information plate;
- check that the gas supply system supplies the necessary amount of
gas to the device and that it is equipped with all the necessary safety
devices prescribed by current regulations.
If the user is absent for a lengthy period, turn off the main gas supply tap.
Do not obstruct the area's ventilation openings where the device is in-
stalled to avoid dangers such as the build up of toxic and explosive sub-
stances. Do not utilize gas tubes to earth electrical devices.

Water connection

Connect the water heater to the water supply and insert a tap to inter-
cept the water above the device. From the front, the cold water input is
on the right and the hot water output is on the left.
Insert the filter into the water valve input fitting.
Remove the plastic nut from the hot water output fittin before
connecting it to the water supply.
Check the water hardness (°f).
In case of high water hardness we recommend to install upstream
of the appliance the water softener device or other device in com-
pliance with the regulations including any revisions.
Ensure that the tubes of you water system are not used to earth your
electrical system or telephone, they are absolutely inappropriate for per-
forming this task.
In a short amount of time this can damage tubes and the device.
Disposal of waste product
This B11BS water heater is supplied with a device for releasing flue gas.
For output of combustion by-products refer to the regulations in force
including any updates.
The gas devices with an attachment for a waste gas flue must be con-
nected directly to properly working chimney or flue pipe; only if these de-
vices are not present is it then permitted to release gases directly outside.
The fitting of devices to a chimney or flue pipe must occur via a smoke
channel. Smoke channels must be connected to a chimney or a smoke
channel in the same or adjacent area to where the device is installed
and must be made of materials resistant to mechanical strain, heat and
the effects of combustion by-products and their condensation. The flue
gas temperature must always be above condensation temperature in all
points of the smoke channel regardless of external conditions.
Flue gas release safety device
The product is equipped with a series of flue gas release safety devices.
The device ensures the correct release of combustion by-products; the
flow of combustible gas to the release conduit and the smoke channel.
The safety device contains a "thermostat", it can stop the flow of gas to
the main burner and the pilot flame.
The safety device can be triggered by the partial or total obstruction of
the release conduit or the smoke channel.
To reset the device it is necessary to press the flue gas thermo-
stat key (Fig. 4) close use a screwdriver and reopening the hot
water tap.
If the device or its electrical connections breaks down, the product can
not be put ON, it ensures a safe condition
If the device or its electrical connections breaks down, the machine ope-
ration is blocked.
If the machine is constantly blocked as a result of the flue gas safety
device, it is necessary to request the assistance of a qualified technician
according to law in force, to check the correct release of flue gas through
the release conduit and/or the smoke channel, according to the installa-
tion regulation.
It is highly prohibited to attempt to modify or remove the flue gas safety
device; this risks the safety of the user and persons in the area. Only a
qualified technician who is authorised by the manufacturer can meddle
with the safety device in order to check it's functionality or to substitute
it if necessary.
If it is necessary to replace the device it is vital to only use "original parts"
supplied by the manufacturer since it has been designed, studied and re-
gulated to be fitted with the water heater.
19

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis