GENERAL SAFETY WARNINGS

The Operation Manual is an integral part of the product and so must
be carefully preserved in order to accompany the product; if it is lost or
damaged another copy can be requested from the Technical Assistance
Centre.
The installation of the device and any other repairs or maintenance
must be performed by qualified personnel according to the law in
force, in compliance with the installing regulations including any
revisions.
It is recommended that trained personnel install the device.
The device must be used according to the manufacturer specifica-
tions. The manufacturer cannot be held contractually or otherwise
responsible for damage caused to persons, animals or objects as a
result of incorrect installation, repair or maintenance or improper
usage.
The product's safety or automatic regulation devices must not be
modified unless performed by the manufacturer.
This device is intended for heating water and therefore must be
connected to a water distribution network who's load and settings
are compatible with the product.
If water spills, turn off the water supply and advise the qualified
personnel at the Technical Assistance Centre.
If the machine is not used for prolonged periods turn off the gas
supply. If there is a risk of the water freezing, empty the water he-
ater.
If the machine breaks down or does not function properly, deacti-
vate it, do not attempt to perform any repairs.
The machine's maintenance must be performed at least once a
year: Book a maintenance session with the Technical Assistance
Centre ahead of time to save wasting time and money afterwards.
When the product has reached the end of its serviceable life, it
shall be disposed of in an environmentally friendly way; ensuring
that the majority of the product is fully recycled in compliance with
the installing regulations including any revisions.
When using the device the following safety rules must be applied:
Do not use the machine for purposes other than those intended by
the manufacturer.
Do not block the intake and dissipation grills or the ventilation
openings in the area where the device is installed with rags, paper
or any other materials.
If a gas leak is detected, do not switch on any electrical devices, te-
lephones or any other objects that could produce a spark. Ventilate
the area by opening the doors and windows and switch off the gas
supply.
Do not place objects on top of the device.
Do not leave flammable containers or substances in the area whe-
re the device is installed.
Do not attempt to repair the machine if it breaks down and/or
works incorrectly.
Children or inexperienced persons are prohibited from using the
device.
It is prohibited to open sealed elements.
To maintain the proper functioning of the device:
- Periodically clean the devices exterior with soapy water, this improves
its appearance as well as preserving it from corrosion in the long term.
- Do not use solvents, powders or abrasive sponges.
- Do not clean the device and/or its parts with flammable materials (e.g.
petrol, alcohol, diesel etc.).

DESCRIPTION OF THE APPLIANCE

NOx identifies the group of the two most important nitrogen oxides:
- NO Nitrogen monoxide (not harmful to humans)
- NO2 Nitrogen dioxide (very harmful to humans and the environment).
NOx is formed during combustion processes at high temperatures.
To reduce NOx emissions it is necessary to cool the flame.
The water inside the water heater, after have been heated by heat exchan-
ger, gets in the burner, cools the flame and gets out to the final user.
The special burner cools the flame and check the airflow necessary for
the combustion, set up "cooled flames" avoiding the loss of thermal effi-
ciency, generating an optimal combustion with low emissions.
INSTALLATION
Regulations
The use of gas devices is controlled by precise regulations.
It is essential to observe all the regulations in force.
Installation of liquid petroleum gas (L.P.G) must comply with all the distri-
butor's requirements and those of the regulations.
Wall mounting
Warning
Do not install this device in an area that contains dust, greasy vapour and/
or corrosive elements.
- The device must be installed on a suitable wall surface in proximity to
a fume disposal flue
- It is vital to leave the minimal distances around the device as shown in
fig 1 to allow for maintenance operations to take place.
Location
The water heater must not be tightly placed in an enclosure or slot, it
should have an adequate flow of air around it
- The water heater must not be placed above a kitchen or other cooking
devices that might deposit grease vapour on its exterior leading to
corrosion
- Surfaces that sensitive to heat (e.g. wood) must be protected using
appropriate insulation.
- Fig. 1 displays the dimensions necessary for wall mounting
Room ventilation
The installation of the water heater must comply with regulations in for-
ce including any updates.
Warning: This device can only be installed in venues that are permanently
ventilated according to regulation in force.
Air circulation
It is vital that areas where gas devices are installed (type B) have access
to the amount of air necessary for the regular combustion of gas as well
as the ventilation of the venue.
- It is prohibited to use an extractor fan, fireplaces and other similar
devices at the same time as the water heater
- The area where the water heater is installed must have a regular flow
of air for ventilation.
Air flow
The flow of air must occur by the following means:
- Permanent openings in the wall that lead outdoors
- Single or collective ventilation ducts.
The air used for ventilation must be taken directly from an outside loca-
tion, that is far from sources of pollution.
Indirect ventilation from adjacent areas are permitted with the following
limitations:
- The adjacent area is equipped with direct ventilation
- The devices within the area to ventilate are connected to a waste duct
- The adjacent area does not contain a bedroom and is not a common
area;
- The adjacent area is not a fire hazard such as a storage area for flam-
mable materials, garage etc.