Herunterladen Inhalt Inhalt Diese Seite drucken

Start Of Operation; Selection Of The Characteristic Curve; Principles Of The Measurements; Moisture Rating ( Wet - Medium - Dry ) - Vwr Rm 20 Bedienungsanleitung

Resistives materialfeuchtemessgerät mit integrierten messnadeln
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

H63.0.21.6C-02_VWR

4.3 Start of operation

Switch the device on with the key
After segment test
P.OF
if the automatic-off-function is activated (p.r.t. chapter0)
The device is ready for measuring afterwards.
4.4

Selection of the characteristic curve

Selection of characteristic curve:
The use of inappropriate characteristics can cause faulty measurements!
Selectable material characteristics:
#
Material
ref
reference (without temperature-compensation)
h.01 Spruce, Pine
h.02 Maple, Birch, Beech, Larch(EUR), Ash(EUR), Fir
h.03 Oak, Ash (AM), Poplar, Douglas Fir
c.01 Cement screed, concrete
c.02 Anhydrite screed
c.03 Gypsum, lime mortar
c.04 Cement mortar
c.05 Aerated concrete
c.06 Limestone
c.07 Brick
c.08 Gypsum plaster

5 Principles of the measurements

5.1 Moisture rating ( WET - MEDIUM - DRY )

In addition to the measuring value there is a moisture rating via bar graph:
Therefore the determination 'wet' or 'dry' is easy and comfortable for most applications and has no longer be deduced
from literature and tables.
However, this rating can only be a first approximate value, because factors like the application field of
the measured material have to be taken into account for the final rating.
Experience and knowledge can only be supported by this instrument, not replaced!

5.2 Moisture u and water content w

Either moisture u or water content w is needed according to the application. The BaleCheck 100 is supposed to be
used the unit moisture u (relating to oven-dry mass). In some cases, like rating of combustibles, the water content w
may be more suitable.
The instrument can be configured to both of the values, please refer to chapter 6.
Moisture u (relating to oven-dry mass) – recommended setting
moisture u[%] = ( (mass
or:
moisture u[%] = (mass
The unit is %u (also common: % atro, weight percent)
mass
:
mass of the sample (= total mass = mass
wet
mass
:
mass of the water contained in the sample
water
mass
:
mass of the oven-dried sample after (water has been evaporated)
dry
Example:
1 kg wet hay that contains 500 g water has a moisture u of 100%
Operating Manual RM 20
.
the device displays some information to its configuration:
by pressing
- mass
) / mass
wet
dry
/ mass
) *100
water
dry
water
the next characteristic curve will be selected.
) *100
dry
+ mass
)
dry
page 5
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

620-1957

Inhaltsverzeichnis