Troubleshooting

1. Difficulties during commissioning
Situation
Spark plug
No ignition
spark
other
Compression
Weak
ignition
spark
The carburettor does
not pump oil
anymore.
regular oil supply,
but weak
compression
regular oil supply
and proper ignition
spark
Cause
Carbon deposit between the
diodes of the spark plug
Ignition coil defective flywheel
magnet too weak
Too much petrol in the combustion
chamber, lousy fuel or water in
the tank
Oil line blocked
Piston rings are worn, the spark
plug is not screwed down, the
cylinder head is not tight, wrong
valve clearance or ignition timing.
Poor contact between the ignition
cap and spark plug
64
Solution
Clean the spark plug.
Adjust the gap
0.6~0.7mm, replace
the spark plug
Replace the ignition
coil or flywheel
Remove the spark
plug and allow it to
dry, and replace the
fuel.
Cleaning the
carburettor and
cleaning the pipes
Replace the screw
tight to replace or
adjust
Replace or check