This manual provides information that is necessary for proper installation and/or operation of the product. Poor in-
stallation and/or improper operating or maintenance will result in unsatisfactory performance and a possible failure.
The manufacturer accepts no liability for any injury or damage to the product resulting from:
• Incorrect assembly or connection, including excess voltage
• Incorrect maintenance or use of spare parts other than original spare parts provided by the manufacturer
• Alterations to the product without express permission from the manufacturer
• Use for purposes other than those described in this manual
Dometic reserves the right to change product appearance and product specifications.

6 Target group

The electrical power supply must be connected by a qualified electrician who has demonstrated skill and
knowledge related to the construction and operation of electrical equipment and installations, and who
is familiar with the applicable regulations of the country in which the equipment is to be installed and/or
used, and has received safety training to identify and avoid the hazards involved.

7 Technical description

The batteries are manufactured with absorbed glass mat (AGM) technology and are completely sealed. The batter-
ies are employing oxygen recombination technology and are deep cycle batteries with valve regulated lead acid (VR-
LA) technology. The batteries are built with special high-density lead-calcium alloy plates, which increase charge re-
tention, allowing low self-discharge and a high number of cycles. The featured separators with reinforced grids make
the batteries resistant to vibration and promote perfect adhesion of the electrolyte to the plates.

8 Installation

WARNING! Damage hazard
When working around a battery, do not allow tools to bridge the battery terminals or short circuit any part
of the battery.
NOTICE! Damage hazard
• To prevent damage to the equipment, deactivate all loads and the charger before battery installa-
tion.
• Battery cables must not be connected to the battery in reverse polarity, otherwise damage to the
device may occur.
• To prevent damage to the equipment, always connect the positive cable first.
Note The battery can be installed in any position or angle.
1.
Connect the battery cables.