WARNING! Risk of injury!
• When operating with a tripod or mast, it must also be ensured that this is sufficiently stable. It is important to ensure
that it is on a level surface. Inclinations are to be avoided.
• Be sure to fix the luminaire with the star grip after it has been placed on your tripod / mast system. This is how you
avoid accidents.
2. Hanging installation
The luminaire can also be operated hanging. This is only permitted in connection with the optional accessory (item no.
1410926021). For this, the ring nut (A) is to be used as a fastening.
ATTENTION!
Make sure your suspension point can support the weight of the luminaire.
• The BASIC version is switched on by connecting to the mains connection.
Disconnecting from the mains causes the luminaire to switch off.
• The SWITCH version is switched on and off using the two pushbuttons (C).
• The DIM version can be switched on and off using the two pushbuttons (E) and the luminosity can also be regulated
using the rotary control (potentiometer, D). Turning the controller clockwise increases the luminosity, turning it
anti-clockwise reduces the brightness of the luminaire.
Fault
Luminaire without function
Failure of only one LED module
Failure of two LED modules
Luminaire cannot be dimmed
DANGER! Electric current!
Maintenance or repair work on the luminaire may only be carried out by qualified electricians.
The relevant safety rules for working on electrical systems apply.
Before any maintenance, repairs or cleaning, the device must always be disconnected from the power supply
by pulling out the mains plug.
Do not use any solvents, alcohol or other chemicals to clean the plastic parts / metal parts.
To remove dirt, dust, oil and grease, etc., use a soft, dry, lint-free cloth.
Handling
Fault
Possible cause
Disconnection from the supply network
Defective LED module
Defective power pack or push button defective
Defective rotary control (potentiometer)
Cleaning and care
Solution
Check the connection to the
power supply
Repair necessary
Repair necessary
Repair necessary
15