14 DUO-NET PLAYER AUDIO PLAYER & STREAMING RECEIVER
IMPORTANT NOTE:
The communication must be started with the client sending the first message
Otherwise, the commands from the client to the EclerNet device will be ignored.
additional information.
TYPE
PARAM1
SYSTEM
CONNECT
DISCONNECT
SUBSCRIPTION_RATE
PING
PONG
PING_INTERVAL
GET
ALL
PRESET_INDEX
PRESET_NAME
DEVICE_NAME
INFO_MODEL
INFO_VERSION
INFO_MAC
INFO_IPLIST
IP_CONFIG
PLAYER_NAME
PARAM2
PARAM3
[PINGPONG]
<Rate>
<PLAYER:A/B>
26
SYSTEM CONNECT
See TP-NET PROTOCOL INTRODUCTION chapter for
PARAM4
DESCRIPTION
Saves the client IP address for responses
and then dumps current device status (with
DATA messages)
Cancel subscriptions and terminates
communication
Alive message from device
Alive message from device
Alive ACK message from client
Dumps current device status (with DATA
messages)
Gets the current PRESET number
Gets the current PRESET name
Gets the Device Name
Gets the Device Model
Gets the Firmware Version
Gets the Device MAC address
Gets the IP parameters of the connected
client devices
Shows the DUO-NET unit's current IP
configuration
Gets the PLAYER A or B NAME
to the EclerNet device.