To let some control systems (like CRESTRON®, EXTRON®, AMX®, RTI®, VITY®,
MEDIALON®, etc.) process the messages more easily, the EclerNet device adds the
character
LF (0x0A)
to the end of each message. This way the client can buffer the
messages to process them, if it's required. The EclerNet device can also handle several
messages received in a single message packet by using the
The available messages are built with one or more fields separated with blank spaces (
= blank space):
<TYPE> [PARAM1]
The first field (TYPE) defines the message type and then, the required parameters for it
(each kind of message requires a given number of parameters). The field
these values:
SYSTEM
GET
SET
INC
DEC
SUBSCRIBE
UNSUBSCRIBE
DATA
ERROR
At the end of this document you'll find all the available messages and their parameters
for each model of the EclerNet compatible devices.
The
SYSTEM, GET, SET, INC, DEC, SUBSCRIBE
sent from the client to the EclerNet device. The
from the device to the client. The only exception is the
SYSTEM
type message that is sent from the EclerNet device when the initial message
from the client to the device was
The communication (using UDP or RS-232) starts when a client sends the message
SYSTEM CONNECT
to the EclerNet device. As far as the UDP communication requires
no connection (unlike the TCP), the EclerNet device stores this client's IP address, and
then uses it as the destination IP address for the messages that it generates
ERROR). After receiving the
configuration using several consecutive
[PARAM2]
[PARAM3]
DATA
SYSTEM CONNECT
SYSTEM CONNECT
message, the device dumps its entire
DATA
messages.
24
LF
delimiter.
[PARAM4][LF]
TYPE
&
UNSUBSCRIBE
messages can be
&
ERROR
messages can be sent
SYSTEM PING
message, that is a
PINGPONG.