Maintenance and Care:

The Infinity XR2 Tri-Star Swivel Adaptor should be returned to its storage case after each use.
NOTE: Ensure component is completely dried after cleaning before returning to case.
If unit is dropped or mishandled, it should be inspected for damage. (REF Inspection
section of this instruction manual) If damage occurs do not use, return the complete
device immediately to Integra LifeSciences for inspection.
Inspection of Components
A routine inspection of the components of the MAYFIELD Infinity XR2 Tri-Star Swivel Adaptor should be
made before each and every procedure to assist in keeping it in good functional condition and to avoid
problems the day of surgery. This check should include the following:
1. Inspect all tension knobs are functioning properly.
2. Check all starburst mating teeth for excessive wear.
3. Verify parts are free of all burrs or sharp corners.
4. Surface is free of cracks and blemishes.
NOTE: Any serious incident that has occurred in relation to the device for the user and/or the patient
should be reported to the manufacturer and the competent authority of the member state in which the
user and/or patient is established.
Integra Standard Warranty
INTEGRA LIFESCIENCES CORPORATION ("INTEGRA") warrants to the original purchaser only that each
new MAYFIELD product is free from manufacturing defects in material and workmanship under normal
use and service for a period of one year (except as otherwise expressly provided as to accessory items)
from the date of delivery by INTEGRA to the first purchaser, but in no event beyond the expiration date
stated on any product labeling.
• Surgical instruments are guaranteed to be free from defects in material and workmanship when
maintained and cleaned properly and used normally for their intended purpose.
• Any covered product that is placed by INTEGRA under a lease, rental or installment purchase
agreement and that requires repair service during the term of such placement agreement shall
be repaired in accordance with the terms of such agreement.
If any covered defect occurs during the warranty period or term of such placement agreement, the
purchaser should communicate directly with INTEGRA's home office. If purchaser seeks to invoke the
terms of this warranty, the product must be returned to INTEGRA at its home office. The defective
product should be returned promptly, properly packaged and postage prepaid. Loss or damage in return
shipment to INTEGRA shall be at CUSTOMER's risk. INTEGRA's sole responsibility under this warranty
shall be repair or replacement, at INTEGRA's sole discretion at INTEGRA's expense, subject to the terms
of this warranty and applicable agreements.