TILTING HAND

The CNTR20 and CNTR32 receivers have the ability to control an output
proportionally (accelerometer): upon pressing a button and with the
handheld in the horizontal starting position, the proportional solenoid
valve is activated at the minimum value. To increase/decrease the speed,
simply tilt the handheld to the left/right by rotating the wrist and keeping
the selected button pressed. As the inclination increases, the speed of
movement increases.
SLOWS
ACCELERATES
82
> In the event of inactivity, the system automatically exits calibration mode after 30 seconds, without changing the current settings.
> Leaving the handheld tilting range, the YELLOW LED flashes indicating that it is over the MINIMUM or MAXIMUM value that can be calibrated.
> For easier calibration, it is preferable to first set the MAXIMUM value and then the MINIMUM value.
> The system is supplied with default proportional solenoid valve values
STARTING POSITION
ACCELERATES
CALIBRATION OF THE PROPORTIONAL VALVE
The calibration procedure allows you to set the minimum and maximum
movement speeds by storing them in the CONTROLLER.
1. With the system switched on, press the START and STOP buttons on the
handheld simultaneously for at least 2 seconds until the RED LED on the
handheld lights up: the system is now in calibration mode.
2. To set the MAXIMUM value, press START and the key corresponding to the
desired function at the same time, with the handheld device level with the
ground. Keeping the buttons pressed, tilt the handheld to the left or right
(by rotating the wrist). Once the desired value has been reached, release
the keys. The MAXIMUM value cannot be less than the MINIMUM value.
3. To set the MINIMUM value, press the key corresponding to the desired
SLOWS
function with the handheld on a plane with respect to the ground.
Keeping the button pressed, tilt the handheld to the left or right (by
rotating the wrist). Once the desired value is reached, release the button.
The MINIMUM value cannot be greater than the MAXIMUM value.
4. Repeat steps 2 and 3 for all desired commands.
5. To exit calibration mode, press the STOP key and make sure the RED LED
turns off.
6. It is now possible to activate the functions with the proportional solenoid
valve calibrated to the saved values.