Safety Notes

Gloves should be worn during installation to prevent crushing and cutting
injuries.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
The product may only be used for bathing, hygienic and body cleaning pur-
poses.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be observed.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of instal-
lation height will also change the minimum height, and that the altered mounting
dimensions must be taken into consideration.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no weak
points.
• The mesh washer must be insert to protect the overhead shower against incoming
dirt by pipework. Incoming dirt leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.
• For removal of the installed EcoSmart (flow limiter) from the shower, the pres-
sure must be lower than 0.2 MPa. With a pressure of more than 0.2 MPa, the
EcoSmart must not be removed.
• The product is not designed to be used with steam baths!
• If the water connections are not stabil mounted, the fitting must be fixed with 2
to 4 extra screws (see page 31, fig. A1 - A11). With this type of installation, take
care not to puncture the water pipe! If the water connections are stabil mounted,
no extra screws are required (see page 32, fig. B1 - B11).
Special information for UK If installing this product with a pump, please be aware
that it has to have negative head switching. This product will not function with a
positive head pump.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Fault
Insufficient water
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
Spout temperature does not correspond with tempera-
ture set
Temperature regulation not possible
Instantaneous heater didn't work with thermostat
4
English
Centre distance:
Connections R 1/2:
The product is exclusively designed for drinking water!

Symbol description

max. 1 MPa
0,3- 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Filters are dirty
- check valve hasn't moved back
Assembly see page 7
Do not use silicone containing acetic acid!
Safety Function (see page 11)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Adjustment (see page 10)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Maintenance (see page 12)
• The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
Dimensions (see page 13)
Flow diagram (see page 13)
Hand shower
overhead shower
Operation (see page 14)
To empty the overhead shower after use, hold it in a slightly inclined
position.
Cleaning (see page 15)
Spare parts (see page 17)
Special accessories (order as an extra)
tile-matching-disk chrome plated #92143000 (see page 17)
Dismounting handle #98369000 (see page 16)
Test certificate (see page 19)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-
thermo cartridge
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 65 ºC
- Exchange thermo cartridge
- Clean the filter / exchange filter
- Exchange check valves
150 ±12 mm
cold right - hot left